Standards compliance
AirTec™ Onyx III (Red) fabric outer meets the following chemical and visibility standards:
AS/NZS 6530:2006
Standard Identifier: Protective Clothing Protection against liquid chemicals test method for resistance of materials to penetration by liquids.
EN471:2003
Standard Identifier: High-visibility warning clothing for professional use. Test methods and requirements.
AirTec™ Flamegard Carbon III (Orange) fabric meets the following standards:
AS/NZS 6530:2006
Standard Identifier: Protective Clothing Protection against liquid chemicals test method for resistance of materials to penetration by liquids.
EN533:1997
Standard Identifier: Protective clothing. Protection against heat and flame. Limited flame spread materials and material assemblies
EN1149-3 Method 2
Standard Identifier: Protective clothing. Electrostatic properties. Test methods for measurement of charge decay
Method 2 anti-static requirements for clothing. This test method is for measurement of charge decay. This means a charge across or through a material leading to a reduction of charge density. Test method 2 measures the strength of the electric field on a recording device.
Other Standards
ISO 6530-2005
Standard Identifier: Protective clothing. Protection against liquid chemicals. Test method for resistance of materials to penetration by liquids.
| Test Liquid | % | Penetration | Repellency | Absorption |
| Sodium Hydroxide* | 50 | 0.0 | 98.2 | 0.0 |
| Hydrochloric Acid | 37 | 0.0 | 91.4 | 1.0 |
| Sulphuric Acid* | 30 | 0.0 | 98.4 | 0.0 |
| Sulphuric Acid* | 98 | 0.0 | 97.9 | 1.9 |
| Nitric Acid | 50 | 0.0 | 98.5 | 0.6 |
| Xylene | 100 | 0.0 | 91.2 | 2.1 |
| Jet Fuel A1* | 100 | 0.0 | 93.8 | 5.4 |
*AirTec Flamegard Carbon III
Chemical Test Standard ASTM F903-03 Performance Results
Resistance of materials used in protective clothing to penetration by liquids.
Procedure C: 0 psig for 5 minutes followed by 2psig (13.8kPa) for 1 minutes followed by 0psig for 54 minutes
Samples of the fabric are clamped over a PTFE test cell and held vertically so that the face of the fabric forms one side of the cell. The cell is filled with the test liquid and a stopwatch started. At all times the fabric is observed for penetration by the liquid.
The fabric is said to fail if a droplet of liquid appears indicating penetration of liquid through to the viewing side of the specimen. Identification of penetration of droplets is effected by use of blotting paper.
| Test Liquid | % | Result |
|---|---|---|
| Sodium Hydroxide | 50 | PASS |
| Sulphuric Acid | 98 | PASS |
| Sulphuric Acid | 30 | PASS |
| Butan-1-ol | 100 | PASS |
| Nitric Acid | 50 | PASS |
| Xylene | 100 | PASS |
| Jet Fuel A1 | 100 | PASS |
| Phenol | 90 | PASS |

AirTec™ — Distributing globally
GSSM co-operates with distributors across the globe, to bring our safety solutions to you.
AirTec™ is tested & proven in Australia with one of the most stringent safety standards in the world.
Opportunities exist on all continents...

Home | AirTec™ | Technology | Distributor zone | Become a distributor | Company | Press releases | Contact us
Copyright 2012 GSSM Pty. Ltd. | Privacy policy | Website Disclaimer | Sitemap Website Design Sydney: Cyrius Media Group